24278929
OBJECTIVE	The aim of this study was to compare clinical outcomes and stability following immediate loading of two types of tapered implants in the partially edentulous posterior maxilla and mandible .
METHODS	A randomized controlled trial with 1 year of follow-up was performed on participants missing two consecutive teeth in a posterior quadrant with tapered implants with a hybrid textured surface .
METHODS	Group 1 received Osstem TSIII HA implants , and group 2 received Zimmer TSV implants .
METHODS	Group 1 implants were 4.5 or 5.0 mm in diameter , and group 2 implants were 4.7 mm in diameter ; all implants were 10 mm long .
METHODS	Subjects received provisional restorations within 48 hours .
METHODS	Definitive restorations were provided 3 months ( mandible ) or 6 months ( maxilla ) later .
METHODS	Outcome measures were survival and success rates , marginal bone level change , implant stability quotient , and peri-implant soft tissue indices .
RESULTS	Fifty participants completed the trial ( group 1 : 52 implants in 26 patients ; group 2 : 48 implants in 24 patients ) .
RESULTS	The success rates were similar -- 98.1 % in group 1 and 97.9 % in group 2 -- at 12 months after immediate loading , but marginal bone loss was significantly different according to the implant design .
RESULTS	Implant stability increased significantly in both arches .
RESULTS	There were no significant differences in soft tissue indices between implant systems .
CONCLUSIONS	If high primary stability is acquired , tapered implants with hybrid textured surfaces are predictable for immediate loading in the posterior maxilla and mandible .
CONCLUSIONS	In spite of the influence of implant design on marginal bone loss , all tapered implants showed successful clinical outcomes and stability in immediate loading .